Information about the HCVF Air Assist Blowers
Location of the air assist blowers in the High Capacity XLS Vacuum Feeder (HCVF):
HCVF Blower Locations
Description
A: Vacuum Blower
B: Air Knife Blower
C: Rear Lead Blower
D: Rear End Blower
E: Front Blower
F: Rear Option Blower
Before adjusting any HCVF air assist blower settings, refer to the following information.
Important:
For all blowers, the settings do not require increasing or decreasing unless misfeed or multifeed faults are occurring.
For the Air Knife Blower, refer to the following information:
The available settings are: Off, Low, Mid, or High.
Low is the slowest speed, and High is the fastest speed.
If the preset value is Off, the blower is not operating. Do not change the setting.
For the Rear Lead Blower and Front Blower, refer to the following information:
The slowest speed is setting 2. Decrease the blower speed only if the current setting is greater than 2.
The fastest speed is setting 13. Increase the blower speed only if the current setting is less than 13.
If the preset value is 1, the blower is not operating. Do not change the setting.
Note: Before changing a blower setting, check the current value. For example, if the current value on a blower is set at 5, to increase the speed by two settings, change the setting to 7.